The Kaye Validator® 2000 itself can be rented together with any necessary counterparts such as thermocouples, SIMs, drywell baths, and IRTDs for an easier, more affordable solution to your personal validation project. The systems are all precalibrated per manufacturer recommendations to NIST traceable standards, ensuring accuracy before use. Features & Benefits. Offers flexibility to operate ...
Kaye HTR-420. The Kaye HTR-420 is the most advanced high temperature calibrator specifically designed to address the capacity and flexibility needs for thermal validation. The HTR-420 is able to calibrate 48 thermocouples at one time and saves hours of time and effort when calibrating or verifying validation sensors.
J-Kem Scientific Temperature Monitor Temperature Controller Model Cole Parmer Digi-Sense Column Heater Traceable Digital Digital Temperature Controller J-Kem Scientific Model Temperature Indicator Yellow Springs Temptale 4 Digi-Sense Temperature Controller Omega Engineering I2r Therm-O-Watch Temperature Chart Recorder 210 Timer Globe Temperature Temp Controller Wet Bulb Sensitech …
THERMOCOUPLE TROUBLESHOOTING REFERENCE > ADVANCED TECHNIQUES > Below are several things to try if your thermocouple is not reading correctly: Most Common Thermocouple Problems . CHECK HARDWARE & SOFTWARE SETUP Make sure your thermocouple is set up properly, as described here. GROUND TC AT ONE PLACE Attach an additional wire from the thermocouple …
The Kaye Validator AVS provides you with a completely new and upgraded validation concept. The AVS console will be the common platform for all validation products going forward. It is dedicated specifically for validation, removing worries about operating systems. The Software is preloaded and ready to go, with a customised interface for validation equipment, simplifying the validation process.
Insulated Thermocouples For critical process validation applications, Kaye Ultra-Premium wire is the proven standard, delivering % accuracy (almost four times more accurate than standard wire). The Kapton® insulated thermocouple wire is rated for continuous use up to 260°C for 3 months and max. temperature of 350°C for 6 days.
Masy’s Ultra-Premium Select Grade, Type-T thermocouples are optimally designed for validation and thermal mapping, from -200°C to 300°C. They are made from ultra-premium select grade wire, which provides the highest purity and uniformity available in the industry. Our thermocouples offer ±°C accuracy at 0°C to ensure precise thermal measurements. Pre-assembled thermocouple sets can ...
Kaye Validator provides thermocouples calibration and calibration verification. Specify all calibration parameters on the Calibration Parameters screen. (The initial set-up file could be copied to set-up a validation cycle and its important to have the calibration set-up correct, as it will be used for post verification.) 1. Specify a two-point calibration, which can be defined using the Kaye ...
There are two main types of autoclave validation equipment- a wired sensor system that involves the use of thermocouples or the use of dedicated data loggers for sterilisers. The Kaye equipment has long been associated with thermal validation in the pharmaceutical manufacturing industry, so reliable is the Kaye Validator 2000 that it is sometimes specified in SOP's. We support the full range ...
Kaye is pleased to announce the introduction of our new Ultra-Premium Grade Autobond Thermocouple Wire. The Autobond wire was designed to eliminate leakage of water or steam through standard Teflon thermocouples. The Autobond wire eliminates the outer clear Teflon jacket which is where 90% of moisture creep occurs and also creates a mold on the inner wires which eliminates any inner air ...
Insulated Thermocouples For critical process validation applications, Kaye Ultra-Premium wire is the proven standard, delivering % accuracy (almost four times more accurate than standard wire). The Kapton® insulated thermocouple wire is rated for continuous use up to 260°C for 3 months and max. temperature of 350°C for 6 days.
The right sensor which perfectly fits to the application and temperature range is part of your validation system. Kaye offers a brought selection of different sensor types suitable for your application needs. Kaye is pleased to announce the introduction of our new Ultra-Premium Grade Autobond Thermocouple …
· Depuis maintenant 60 ans, Kaye est leader dans les systèmes de validation thermique destinés principalement à l'industrie pharmaceutique. La large gamme de produits de Kaye (sondes embarquées, sondes radio fréquences, centrales filaires, systèmes de validation de nettoyage et de monitoring, générateurs de température) répond avec un haut niveau d'exigence aux différentes …
Kaye is pleased to announce the introduction of our new Ultra-Premium Grade Autobond Thermocouple Wire. The Autobond wire was designed to eliminate leakage of water or steam through standard Teflon thermocouples. The Autobond wire eliminates the outer clear Teflon jacket which is where 90% of moisture creep occurs and also creates a mold on the inner wires which eliminates any inner air ...
The thermocouple is widely utilized in most applications for temperature measurement, especially for sterilizer heat validation studies. It is a simple device being only two wires joined together ...
Thermocouple Entry Gland. Tri Clamp Entry Glands in Various Sizes Includes Gaskets Steam Quality Test Kit. Incuding Balance, Weights and all Test Equipment for the following Tests: Dryness Test; Non Condensable Gases Test; Superheat Test Pressure Transducer. Tri Clamp Pressure Transducer 0-4mBar Absolute Cable and UKAD Calibration Certificate Connections for Kaye Validator 2000. …
The Haven accepts up to 36 thermocouples. Kaye IRTD & Digitron IRTD The Digitron IRTD provides a traceable standard that is used to correct the temperature readings of the thermocouples. Digitron standard system Measurement accuracy: C; Range: -183 C to 200 C SYSTEM ACCESS The Validator 2000 software is designed for three levels of users. Each level has specific permissions …
· This validation discipline primarily uses Kaye Validator T-type thermocouples or remote temperature sensors (Ellab, DataTrace, etc.) along with biological indicators to provide a biological test complement. The common method to secure the thermocouple/sensor and biological indicator in place is by using zip-ties. But, these thermocouples and sensors come in a variety of sizes and shapes and ...
· Shipping: Reduced shipping costs when compared to a comparable Kaye Validator 2000, as each Vaisala VL-1416-44V, with four 25’ thermocouples attached, weighs approximately 12 ounces. Efficiency: The loggers can be preprogrammed prior to arriving to the testing site. For fast deployment and installation of the sensors, the thermocouples can be ...
Manufacturer: GE Sensing; Model: X2010; Kaye Validator model X2010 Standalone temperature validator; Accepts up to 36 inputs in any combination of thermocouple, voltage, or current inputs; Can be used with Kaye software (Not included) for calibration, qualification and reporting; USB interface for loading setups, collecting data, upgrading firmware ; 30-minute battery backup; Sensor input ...
The Amphenol Kaye Validator 2000 is a thermocouple based datalogger routinely used within the pharmaceutical Industry. The Validator 2000 accepts up to 36 sensors, we mainly use it for Type T thermocouples and pressure inputs. Uses We predominantly use the Kaye Validator for autoclave validation, SIP validation, liquid nitrogen, depyrogenation tunnels/ovens and lyophiliser validation. The Kaye ...